Information de reference pour ce titreAccession Number: | 00000539-201110000-00023.
|
Author: | McDonald, Sarah FRCA *; Fernando, Roshan FRCA *; Ashpole, Keri FRCA *; Columb, Malachy FRCA +
|
Institution: | From the (*)Department of Anesthesia, Royal Free Hospital NHS Trust, London; and (+)Department of Anesthesia, University Hospital of South Manchester NHS Foundation Trust, Wythenshawe, Manchester, United Kingdom.
|
Title: | |
Source: | Anesthesia & Analgesia. 113(4):803-810, October 2011.
|
Abstract: | BACKGROUND: Minimizing hypotension associated with spinal anesthesia for cesarean delivery by administration of IV fluids and vasopressors reduces fetal and maternal morbidity. Most studies have concentrated on noninvasive systolic blood pressure (SBP) measurements to evaluate the effect of such regimens. We used a suprasternal Doppler flow technique to measure maternal cardiac output (CO) variables in parturients receiving a phenylephrine infusion combined with the rapid administration of crystalloid or colloid solution at the time of initiation of anesthesia (coload). We hypothesized that a colloid coload compared with a crystalloid coload would produce a larger sustained increase in CO and therefore reduce vasopressor requirements.
METHODS: We recruited 60 healthy term women scheduled for elective cesarean delivery under spinal anesthesia for this randomized double-blind study. Baseline heart rate, baseline SBP, and CO variables including stroke volume, corrected flow time, and contractility were recorded in the left lateral tilt position. At the time of spinal injection, subjects were allocated to receive a rapid 1-L coload of either 6% w/v hydroxyethyl starch solution (HES) or Hartmann (crystalloid) solution (HS). A phenylephrine infusion was titrated to maintain maternal baseline SBP. CO was measured at 5-minute intervals for 20 minutes after initiation of spinal anesthesia. The primary outcome, CO, was compared between groups, as were secondary outcomes: phenylephrine dose and maternal hemodynamic and fetal outcome data.
RESULTS: Maternal demographics, surgical times, and fetal outcome data were similar between groups. There were no significant differences between groups in any measured CO variable at any time point. CO was transiently higher than baseline at 5 minutes in the HS group and at 5 and 10 minutes in the HES group (range, 0.13-1.74 L/min); the overall mean difference in CO between crystalloid and colloid over the study period was 0.06 L/min (95% confidence interval: -0.46 to 0.58). Stroke volume was higher than baseline in both groups throughout; peak velocity was consistently higher than baseline only in the HES group; and corrected flow time increased in both groups; the effect was transient in the HS but sustained in the HES group. Heart rate was not different at any time point within or between groups but did decrease over time. The total phenylephrine dose from time of spinal anesthesia to delivery was similar between groups.
CONCLUSION: We found no difference in CO in women randomized to colloid or crystalloid coload. In addition, there were no differences in vasopressor requirements or hemodynamic stability. We conclude that there is no advantage in using colloid over crystalloid when used in combination with a phenylephrine infusion during spinal anesthesia for elective cesarean delivery.
(C) 2011 International Anesthesia Research Society
|
References: | 1. Smiley RM. Burden of proof. Anesthesiology 2009;111:470-2
2. Kamenik M, Paver-Erzen V. The effects of lactated Ringer's solution infusion on cardiac output changes after spinal anesthesia. Anesth Analg 2001;92:710-4
3. Ueyama H, He YL, Tanigami H, Mashimo T, Yoshiya I. Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective cesarean section. Anesthesiology 1999;91:1571-6
4. Tamilselvan P, Fernando R, Bray J, Sodhi M, Columb M. The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial. Anesth Analg 2009;109:1916-21
5. Riley ET, Cohen SE, Rubenstein AJ, Flanagan B. Prevention of hypotension after spinal anesthesia for cesarean section: six percent hetastarch versus lactated Ringer's solution. Anesth Analg 1995;81:838-42
6. Siddik SM, Aouad MT, Kai GE, Sfeir MM, Baraka AS. Hydroxyethylstarch 10% is superior to Ringer's solution for preloading before spinal anesthesia for cesarean section. Can J Anaesth 2000;47:616-21
7. Karinin J, Rasanen J, Alahuhta S, Joupilla R, Jouppila P. Effect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section. Br J Anaesth 1995;75:531-5
8. French GW, White JB, Howell SJ, Popat M. Comparison of pentastarch and Hartmann's solution for volume preloading in spinal anaesthesia for elective caesarean section. Br J Anaesth 1999;83:475-7
9. Dyer RA, Farina Z, Joubert IA, Du Toit P, Meyer M, Torr G, Wells K, James MF. Crystalloid preload versus rapid crystalloid administration after induction of spinal anaesthesia (coload) for elective caesarean section. Anaesth Intensive Care 2004;32:351-7
10. Teoh WH, Sia AT. Colloid preload versus coload for spinal anesthesia for cesarean delivery: the effects on maternal cardiac output. Anesth Analg 2009;108:1592-8
11. Siddik-Sayyid SM, Nasr VG, Taha SK, Zbeide RA, Shehade JM, Al Alami AA, Mokadem FH, Abdallah FW, Baraka AS, Aouad MT. A randomized trial comparing colloid preload to coload during spinal anesthesia for elective cesarean delivery. Anesth Analg 2009;109:1219-24
12. Carvalho B, Mercier FJ, Riley ET, Brummel C, Cohen SE. Hetastarch co-loading is as effective as pre-loading for the prevention of hypotension following spinal anesthesia for cesarean delivery. Int J Obstet Anesth 2009;18:150-5
13. Nishikawa K, Yokoyama N, Saito S, Goto F. Comparison of effects of rapid colloid loading before and after spinal anesthesia on maternal hemodynamics and neonatal outcomes in cesarean section. J Clin Monit Comput 2007;21:125-9
14. Robson SC, Boys RJ, Rodeck C, Morgan B. Maternal and fetal haemodynamic effects of spinal and extradural anaesthesia for elective caesarean section. Br J Anaesth 1992;68:54-9
15. Ngan Kee WD, Khaw KS, Ng FF. Prevention of hypotension during spinal anesthesia for cesarean delivery: an effective technique using combination phenylephrine infusion and crystalloid cohydration. Anesthesiology 2005;103:744-50
16. McLennan FM, Haites NE, Mackenzie JD, Daniel MK, Rawles JM. Reproducibility of linear cardiac output measurement by Doppler ultrasound alone. Br Heart J 1986;55:25-31
17. Kocarev M, Watkins E, McLure H, Columb M, Lyons G. Sensory testing of spinal anaesthesia for cesarean section: differential block and variability. Int J Obstet Anesth 2010;19:261-5
18. Rout CC, Rocke DA, Levin J, Gouws E, Reddy D. A reevaluation of the role of crystalloid preload in the prevention of hypotension associated with spinal anesthesia for elective cesarean section. Anesthesiology 1993;79:262-9
19. Jackson R, Reid JA, Thorburn J. Volume preloading is not essential to prevent spinal-induced hypotension at caesarean section. Br J Anaesth 1995;75:262-5
20. Park GE, Hauch MA, Curlin F, Datta S, Bader AM. The effects of varying volumes of crystalloid administration before cesarean delivery on maternal hemodynamics and colloid osmotic pressure. Anesth Analg 1996;83:299-303
21. Ngan Kee WD, Khaw KS, Ng FF. Comparison of phenylephrine infusion regimens for maintaining maternal blood pressure during spinal anaesthesia for caesarean section. Br J Anaesth 2004;92:469-74
22. Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology 2009;111:753-65
23. Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg 2010;111:1230-7
24. Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology 2008;109:856-63
25. Barron ME, Wilkes MM, Navickis RJ. A systematic review of the comparative safety of colloids. Arch Surg 2004;139:552-63
|
Language: | English.
|