Information de reference pour ce titreAccession Number: | 00080111-200808000-00004.
|
Author: | Anderson, David J. *
|
Institution: | Electrical Engineering and Computer Science, Biomedical Engineering, Kresge Hearing Research Institute, University of Michigan, 1301 East Ann Street, Ann Arbor, MI 48109-0506, USA
|
Title: | Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research.[Article]
|
Source: | Hearing Research. 242(1):31-41, August 2008.
|
Abstract: | Microelectrode arrays offer the auditory systems physiologists many opportunities through a number of electrode technologies. In particular, silicon substrate electrode arrays offer a large design space including choice of layout plan, range of surface areas for active sites, a choice of site materials and high spatial resolution. Further, most designs can double as recording and stimulation electrodes in the same preparation. Scala tympani auditory prosthesis research has been aided by mapping electrodes in the cortex and the inferior colliculus to assess the CNS responses to peripheral stimulation. More recently silicon stimulation electrodes placed in the auditory nerve, cochlear nucleus and the inferior colliculus have advanced the exploration of alternative stimulation sites for auditory prostheses. Multiplication of results from experimental effort by simultaneously stimulating several locations, or by acquiring several streams of data synchronized to the same stimulation event, is a commonly sought after advantage. Examples of inherently multichannel functions which are not possible with single electrode sites include (1) current steering resulting in more focused stimulation, (2) improved signal-to-noise ratio (SNR) for recording when noise and/or neural signals appear on more than one site and (3) current source density (CSD) measurements. Still more powerful are methods that exploit closely-spaced recording and stimulation sites to improve detailed interrogation of the surrounding neural domain. Here, we discuss thin-film recording/stimulation arrays on silicon substrates. These electrode arrays have been shown to be valuable because of their precision coupled with reproducibility in an ever expanding design space. The shape of the electrode substrate can be customized to accommodate use in cortical, deep and peripheral neural structures while flexible cables, fluid delivery and novel coatings have been added to broaden their application. The use of iridium oxide as the neural interface site material has increased the efficiency of charge transfer for stimulation and lowered impedance for recording electrodes.
(C) 2008Elsevier, Inc.
|
Author Keywords: | Multichannel electrode arrays; Neural stimulation; Single unit recordings; Array data processing.
|
References: | Abeles, M., Goldstein, M.H., 1977. Multispike train analysis. Proc. Inst. Electr. Electron. 65, 762-773.
Anderson, D.J., Najafi, K., Tanghe, S.J., Evans, D.A., Levy, K.L., Hetke, J.F., Xue, X., Zappia, J.J., Wise, K.D., 1989. Batch-fabricated thin-film electrodes for stimulation of the central auditory system. IEEE Trans. Biomed. Eng. 36, 693-704.
Anderson, D.J., Oweiss, K.G., Bierer, S.M., 2001. Sensor arrays in the micro-environment of the brain. In: Acoustics, Speech, and Signal Processing, (ICASSP'01), vol. 6, pp. 3433-3436.
Badi, A.N., Kertesz, T.R., Gurgel, R.K., Shelton, C., Normann, R.A., 2003. Development of a novel eighth-nerve intraneural auditory neuroprosthesis. Laryngoscope. 113, 833-842.
Bai, Q., Wise, K.D., Anderson, D.J., 2000. A high-yield microassembly structure for three-dimensional microelectrode arrays. IEEE Trans. Biomed. Eng. 47, 281-289.
BeMent, S.L., Wise, K.D., Anderson, D.J., Najafi, K., Drake, K.L., 1986. Solid-state electrodes for multichannel multiplexed intracortical neuronal recording. IEEE Trans. Biomed. Eng. 33, 693-704.
Bierer, J.A., Middlebrooks, J.C., 2002. Auditory cortical images of cochlear-implant stimuli: dependence on electrode configuration. J. Neurophysiol. 87, 478-492.
Biran, R., Martin, D.C., Tresco, P.A., 2005. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays. Exp. Neurol. 195, 115-126.
Blanche, T.J., Spacek, M.A., Hetke, J.F., Swindale, N.V., 2005. Polytrodes: high-density silicon electrode arrays for large-scale multiunit recording. J. Neurophysiol. 93, 2987-3000.
Bragin, A., Hetke, J., Wilson, C.L., Anderson, D.J., Engel, J. Jr, Buzsaki, G., 2000. Multiple site silicon-based probes for chronic recordings in freely moving rats: implantation, recording and histological verification. J. Neurosci. Methods. 98, 77-82.
Brown, G.D., Yamada, S., Sejnowski, T.J., 2001. Independent component analysis at the neural cocktail party. Trends Neurosci. 24, 54-63.
Buzsaki, G., 2004. Large-scale recording of neuronal ensembles. Nat. Neurosci. 7, 446-451.
Chen, J.K., Wise, K.D., Hetke, J.F., Bledsoe, S.C. Jr, 1997. A multichannel neural probe for selective chemical delivery at the cellular level. IEEE Trans. Biomed. Eng. 44, 760-769.
Cui, X., Hetke, J.F., Wiler, J.A., Anderson, D.J., Martin, D.C., 2001. Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes. Sensor Actuat. A - Phys. 93, 8-18.
Drake, K.L., Wise, K.D., Farraye, J., Anderson, D.J., BeMent, S.L., 1988. Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity. IEEE Trans. Biomed. Eng. 35, 719-732.
Edell, D.J., 1986. A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves. IEEE Trans. Biomed. Eng. 33, 203-214.
Edell, D.J., Toi, V.V., McNeil, V.M., Clark, L.D., 1992. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans. Biomed. Eng. 39, 635-643.
Edwards, C.E., Finger, P.A., Anderson, D.J., Wiler, J.A., Hetke, J.F., Altschuler, R.A., 1997. A technique for in vivo morphological evaluation of chronically implanted neuronal silicon substrate electrodes for confocal microscopy. Abstracts for Microscopy and Microanalysis, Cleveland, OH, p. 351.
Evans, D.E., Niparko, J.K., Miller, J.M., Jyung, R.W., Anderson, D.J., 1989. Multiple-channel stimulation of the cochlear nucleus. Otolaryng. Head Neck. 101, 651-657.
Gingerich, M.D., Hetke, J.F., Anderson, D.J., Wise, K.D., 2001. A 256-site CMOS microelectrode array for multipoint stimulation and recording in the central nervous system. In: Digest, International Conference on Solid-State Sensors and Actuators, pp. 416-419.
Gray, C.M., Maldonado, P.E., Wilson, M., McNaughton, B., 1995. Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex. J. Neurosci. Methods. 63, 43-54.
Hassibi, A., Navid, R., Dutton, R.W., Lee, T.H., 2004. Comprehensive study of noise processes in electrode electrolyte interfaces. J. Appl. Phys. 96, 1074-1082.
Hetke, J.F., Lund, J.L., Najafi, K., Wise, K.D., Anderson, D.J., 1994. Silicon ribbon cables for chronically implantable microelectrode arrays. IEEE Trans. Biomed. Eng. 41, 314-321.
Ji, J., Wise, K.D., 1992. An implantable CMOS circuit interface for multiplexed microelectrode recording arrays. IEEE J. Solid-State Circ. 27, 433-443.
Johnson, M.D., Otto, K.J., Kipke, D.R., 2005. Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances. IEEE Trans. Neuro. Syst. Rehabil. 13, 160-165.
Jolly, C.N., Spelman, F.A., Clopton, B.M., 1996. Quadrupolar stimulation for cochlear prostheses: modeling and experimental data. IEEE Trans. Biomed. Eng. 43, 857-865.
Kandel, A., Buzsaski, G., 1997. Cellular-synaptic generation of sleep spindles, spike-and-wave discharges, and evoked thalamocortical responses in the neocortex of the rat. J. Neurosci. 17, 6783-6797.
Kim, D.-H., Martin, D.C., 2006. Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery. Biomaterials. 27, 3031-3037.
Kim, Y.T., Hitchcock, R.W., Bridge, M.J., Tresco, P.A., 2004. Chronic response of adult rat brain tissue to implants anchored to the skull. Biomaterials. 25, 2229-2237.
Kipke, D.R., Vetter, R.J., Williams, J.C., Hetke, J.F., 2003. Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex. IEEE Trans. Neuro. Syst. Rehabil. 11, 151-155.
Kovacs, G.T.A., 1998. Micromachined Transducers Sourcebook, first ed.. McGraw Hill, New York, p. 688 (Chapter 8).
Lempka, S.F., Johnson, M.D., Barnett, D.W., Moffitt, M.A., Otto, K.J., Kipke, D.R., McIntryre, C.C., 2006. Optimization of microelectrode design for cortical recording based on thermal noise considerations. In: Proceedings of the Institute of Electrical and Electronics 28th EMBS Conference FrC14.3.
Lim, H.H., Anderson, D.J., 2006. Auditory cortical responses to electrical stimulation of the inferior colliculus: implications for an auditory midbrain implant. J. Neurophysiol. 96, 975-988.
Lim, H.H., Anderson, D.J., 2007. Antidromic activation reveals tonotopically organized projections from primary auditory cortex to the central nucleus of the inferior colliculus in guinea pig. J. Neurophysiol. 97, 1413-1427.
Lim, H.H., Lenarz, T., Anderson, D.J., Lenarz, M., 2008. The auditory midbrain implant: Effects of electrode location. Hear. Res. 242, 74-85.
Martinez-Santiesteban, F.M., Swanson, S.D., Noll, D.C., Anderson, D.J., 2006. Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: design criteria, test, and recommendations. IEEE Trans. Biomed. Eng. 53, 547-558.
Martinez-Santiesteban, F.M., Swanson, S.D., Noll, D.C., Anderson, D.J., 2007. Magnetic field perturbation of neural recording and stimulating microelectrodes. Phys. Med. Biol. 52, 2073-2088.
May, G.A., Shamma, S.A., White, R.L., 1979. A tantalum-on-sapphire microelectrode array. IEEE Trans. Electron. Dev. 26, 1932-1939.
McCreery, D., Lossinsky, A., Pikov, V., 2007. Performance of multisite silicon microprobes implanted chronically in the ventral cochlear nucleus of the cat. IEEE Trans. Biomed. Eng. 54, 1042-1052.
McCreery, 2008. Cochlear nucleus auditory prostheses. Hear. Res. 242, 64-73.
McNaughton, B.L., O'Keefe, J.O., Barnes, C.A., 1983. The sterotrode: a new technique for simultaneous isolation of several single units in the central nervous system from multiple unit records. J. Neurosci. Methods. 8, 391-397.
Mensinger, A.F., Anderson, D.J., Buchko, C.J., Johnson, M.A., Martin, D.C., Tresco, P.A., Silver, R.B., Highstein, S.M., 2000. Chronic recording of regenerating VIIIth nerve axons with a sieve electrode. J. Neurophysiol. 83, 611-615.
Merzenich, M.M., Reid, M.D., 1974. Representation of the cochlea within the inferior colliculus of the cat. Brain Res. 77, 397-415.
Middlebrooks, J.C., Bierer, J.A., 2002. Auditory cortical images of cochlear-implant stimuli: coding of stimulus channel and current level. J. Neurophysiol. 87, 493-507.
Middlebrooks, J.C., Snyder, R.L., 2007. Auditory prosthesis with a penetrating nerve array. JARO. 8, 258-279.
Moxon, K.A., Leiser, S.C., Gerhardt, G.A., Barbee, K.A., Chapin, J.K., 2004. Ceramic-based multisite electrode arrays for chronic single-neuron recording. IEEE Trans. Biomed. Eng. 51, 647-656.
Muller-Preuss, P., Mitzdorf, U., 1984. Functional anatomy of the inferior colliculus and the auditory cortex: current source density analyses of click-evoked potentials. Hear. Res. 16, 133-142.
Najafi, K., Wise, K.D., Mochizuki, T., 1985. A high-yield IC-compatible multichannel recording array. IEEE Trans. Electron. Dev. 32, 1206-1211.
Nicholson, C., Freeman, J.A., 1975. Theory of current source-density analysis and determination of conductivity tensor for anuran cerebellum. J. Neurophysiol. 38, 356-368.
Nicolelis, M.A., Dimitrov, D., Camena, J.M., Crist, R., Lehew, G., Kralik, J.D., 2003. Chronic, multisite, multielectrode recordings in macaque monkeys. PNAS. 100, 11041-11046.
Otto, K.J., Johnson, M.D., Kipke, D.R., 2006. Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes. IEEE Trans. Biomed. Eng. 53, 333-340.
Oweiss, K., Anderson, D.J., 2007. Tracking signal subspace invariance for blind separation and classification of nonorthogonal sources in correlated noise. EURASIP J. Appl. Sig. P, 20p, Article ID 37485.
Pang, C., Cham, J.G., Nenadic, Z., Musallam, S., Tai, Y.-C., Burdick, J.W., Anderson, R.A., 2005. A new multi-site probe array with monolithically integrated parylene flexible cable for neural prostheses. In: Proceedings of the Institute of Electrical and Electronics 27th EMBS Conference, pp. 7114-7117.
Perkel, D.H., Gerstein, G.L., Moore, G.P., 1967a. Neuronal spike trains and stochastic point processes: II. Simultaneous spike trains. Biophys. J. 7, 419-440.
Perkel, D.H., Gerstein, G.L., Moore, G.P., 1967b. Neuronal spike trains and stochastic point processes: I. The single spike train. Biophys. J. 7, 391-418.
Pickard, R.S., Joseph, P.L., Collins, A.J., Hicks, R.C.J., 1979. Flexible printed-circuit probe for electrophysiology. Med. Biol. Eng. Comput. 17, 261-267.
Prechtl, J.C., Bullock, T.H., Kleinfeld, D., 2000. Direct evidence for local oscillatory current sources and intracortical phase gradients in turtle visual cortex. PNAS. 97, 877-882.
Prohaska, O.J., Olcaytug, F.P., Pfundner, P., Dragaun, H., 1986. Thin-film multiple electrode probes: possibilities and limitations. IEEE Trans. Biomed. Eng. 33, 223-229.
Rathnasingham, R., Kipke, D.R., Bledsoe, S.C. Jr, McLaren, J.D., 2004. Characterization of implantable microfabricated fluid delivery devices. IEEE Trans. Biomed. Eng. 51, 138-145.
Robblee, L.S., Lefko, J.L., Brummer, S.B., 1983. Activated iridium: an electrode suitable for reversible charge injection in saline solution. J. Electrochem. Soc. 130, 731-733.
Robinson, D.A., 1968. The electrical properties of metal microelectrodes. Proc. IEEE. 56, 1065-1071.
Rousche, P.J., Normann, R.A., 1998. Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex. J. Neurosci. Methods. 82, 1-15.
Rousche, P.J., Pellinen, D.S., Pivin, D.P., Williams, J.C., Vetter, R.J., Kipke, D.R., 2001. Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans. Biomed. Eng. 48, 361-371.
Shain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., Turner, J.N., 2003. Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies. IEEE Trans. Neuro. Syst. Rehabil. 11, 186-188.
Snellings, A., Anderson, D.J., Aldridge, J.W., 2006. Improved signal and reduced noise in neural recordings from close-spaced electrode arrays using independent component analysis as a preprocessor. J. Neurosci. Methods. 150, 254-264.
Snyder, R.L., Bierer, J.A., Middlebrooks, J.C., 2004. Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation. JARO. 5, 305-322.
Spataro, L., Dilgen, J., Retterer, S., Spence, A.J., Isaacson, M., Turner, J.N., Shain, W., 2005. Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex. Exp. Neurol. 194, 289-300.
Stark, H., Woods, J.W.Probability, Random Processes, and Estimation Theory for Engineers. second ed. Upper Saddle River, NJ: Prentice Hall; 1994.
Starr, A., Wise, K.D., Csongradi, J., 1973. An evaluation of photoengraved microelectrodes for extracellular single-unit recording. IEEE Trans. Biomed. Eng. 20, 291-293.
Szarowski, D.H., Andersen, M.D., Retterer, S., Spence, A.J., Isaacson, M., Craighead, H.G., Turner, J.N., Shain, W., 2003. Brain responses to micro-machined silicon devices. Brain Res. 983, 23-35.
Tanghe, S.J., Wise, K.D., 1992. A 16-Channel CMOS neural stimulating array. J. Solid-State Circ. 27, 1819-1825.
Vetter, R.J., Williams, J.C., Hetke, J.F., Nunamaker, E.A., Kipke, D.R., 2004. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex. IEEE Trans. Biomed. Eng. 51, 896-904.
Weiland, J.D., Anderson, D.J., 2000. Chronic neural stimulation with thin-film, iridium oxide electrodes. IEEE Trans. Biomed. Eng. 47, 911-918.
Wise, K.D., Angell, J.B., 1975. A low-capacitance multielectrode probe for use in extracellular neurophysiology. IEEE Trans. Biomed. Eng. 22, 212-219.
Wise, K.D., Angell, J.B., Starr, A., 1970. An integrated-circuit approach to extracellular microelectrodes. IEEE Trans. Biomed. Eng. 17, 238-247.
Wise, K.D., Anderson, D.J., Hetke, J.F., Kipke, D.R., Najafi, K., 2004. Wireless implantable microsystems: high-density electronic interfaces to the nervous system. Proc. IEEE. 92, 76-97.
Wise, K.D., Bhatti, P.T., Wang, J., Friedrich, C.R., 2008. High-density cochlear implants with position sensing and control. Hear. Res. 242, 22-30.
Yao, Y., Gulari, M.N., Casey, B., Wiler, J.A., Wise, K.D., 2007. Silicon microelectrodes with flexible integrated cables for neural implant applications. In: Proceedings of the Institute of Electrical and Electronics EMBS Conference on Neural Engineering, Article ID. FrD3.20.
|
Language: | English.
|
Document Type: | Articles.
|
Journal Subset: | Clinical Medicine. Health Professions.
|
ISSN: | 0378-5955
|
DOI Number: | https://dx.doi.org/10.1016/j.hea...- ouverture dans une nouvelle fenêtre
|
Annotation(s) | |
|
|